Home

SMART LCD-PROGRAMMABLE BIOCLEAN SANITIZER DISPENSER

 

Install on Urinals, Water-closets and all type of Toilet System for Automatic Toilet and Drain Maintenance.

PRODUCT FEATURES: 

Refillable Metered Pump Cartridge, Guaranteed 4,000 dosages per refill, LCD Control Panel, Start / Stop Setting,  Dosage Frequency Setting Function, Day Off Selection, Reset Button, Test Button, Key Lock, Battery Status Indicator, Built-in Way Valve, Waterproofed Housing, Stainless Steel Connection Kit, Operates on 2 "D" size Alkaline Batteries lasts 12 months.

 

 

INSTALLATION SEQUENCE OF BIO CLEAN BCS-325

 

OPERATION INSTRUCTIONS:

SWITCHING ON UNIT:

Open dispenser cover, using key supplied

Insert two "D" size batteries

Install the Bioclean/sanitizer refill bottle by inserting the tip into the nozzle

Turn ON dispenser using ON/OFF switch

When unit is turn ON, LCD automatically displays Time Clock Setting.

 

TIME CLOCK SETTING:

Press MINUTE and HOUR button to adjust clock setting to desired time (To scroll, press and hold)

Press DAY button to set the actual day.

 

SET OPERATION MODE:  

Step 1. Select Start Time

Press SERVICE button to select Start Time mode (STR).

Press MINUTE and HOUR button to select desired start time.

 

Step 2. Select Stop Time

Press SERVICE button to select Stop Time mode (STP).

Press MINUTE and HOUR button to select desired stop time.

 

Step 3. Select Dispensing Interval

Press SERVICE button to select interval mode (INT).

Press MINUTE button to set desired dispensing interval. Default setting is 15 minutes.

 

Step 4. Select Off Day

Press SERVICE button to select Sleep mode (SLP).

Press DAY button to select Off Day.

Note: When no "Off Day" has been selected before

 

Press DAY button, 1st. time to activate required Off Day.

Press DAY button, 2nd. time to deactivate Off Day.

Note: When "Off Day" has been selected and programmed

 

Press DAY button once only to deactivate the Off Day.

 

SET MAINTENANCE MODE:  

Step 1. Check Battery Status

Press and hold SERVICE button for 3 seconds to check status of batteries.

When battery is low, LCD will display battery sign with a "X"

 

Step 2. Check Refill Balance

While  in Battery Status mode, press SERVICE button again

Display will show refill balance in number of days

 

Step 3. Changing Batteries

Dispenser will hold memory for 60 seconds, allowing you to change batteries without losing settings.

 

Step 4. Changing Refill

Press RESET button after inserting new refill

 

INSTALLATION INSTRUCTIONS:  

1. Choose location of connection on flush pipe. Determine which side of the pipe to drill.

 

2. Drill a hole in the pipe at the mark. WARNING: DRILL THE HOLE THROUGH ONE SIDE OF THE PIPE ONLY.

 

3. Assemble the installation kit. Insert stainless steel pipe into fitting on the pipe and dispenser. (Refer to the installation sequence below)

 

4. Position the dispenser on the wall and mark the location through the screw mount hole on the dispenser for location to drill.

 

5. Drill hole and mount dispenser on the wall with screws and anchors provided in the installation kit.

 

6. Tighten the compression nuts to secure the installation.

 

7. Flush the fixture to test for any leakage.

For more information how BIO CLEAN & BIO PLUS Technology can help solve your malodor and drain blockages problems, contact your Calfarme representative.

New Launched! Calfarme BIO PLUS Mix-n-Dispenser Station

Presentation for Calfarme BIO TABS & BIO PLUS Waterless Urinal Drain Maintenance Systems

FOAM WIPE Toilet Seat Sanitizer! Safe for skin contacts

More information | About Us | News | Products | Business Opportunities

 ISO 9001:2008 | ISO 14001:2004 | SINGAPORE GREEN LABEL CERTIFIED

 

A MEMBER OF SINGAPORE GREEN BUILDING COUNCIL

2015 Calfarme.com. All Rights Reserved.